
Contract Battery Manufacturing · Est. 2018
Your Product.
Our Line.
Zero Compromise.
From cell sourcing to certified pack delivery — we run the line EV startups, solar storage companies, and industrial OEMs can't justify building themselves.
4 GWh
Annual Capacity
99.4%
First-Pass Yield
6
Active Certifications
Virtual Supplier Audit
Verify Every
Certification.
Scroll through our compliance stack. Each section shows the exact test, equipment used, and pass documentation — the same evidence your procurement team will request.
Compliance Checklist
UL 9540A
Energy Storage System Safety
IEC 62619
Secondary Lithium Cells — Safety
UN 38.3
Lithium Battery Transport Testing
ISO 9001:2015
Quality Management System
Cell Sourcing
Tier-1 verified suppliers only
Weld Integrity
100% pull-test on spot welds
Pack Traceability
Serial → cell-level MES record
Currently Viewing
UL 9540A
Underwriters Laboratories
Energy Storage System Safety
Underwriters Laboratories

Cell-level, module-level, and unit-level fire propagation testing. Every pack geometry we manufacture runs through a dedicated thermal runaway propagation test in our UL-certified test chamber.
Test Protocol
Thermal Runaway Propagation Test
Equipment
Forced-air calorimeter, 8-channel thermocouple array, high-speed IR camera (320fps)
Pass Result
No propagation beyond initiating cell in 47 consecutive pack configurations
Secondary Lithium Cells — Safety
International Electrotechnical Commission

Industrial application safety requirements covering overcharge, over-discharge, short circuit, crush, and thermal abuse. Our IEC 62619 protocol runs 100% sampling on every production lot, not a statistical subset.
Test Protocol
Overcharge / Short-Circuit / Crush Matrix
Equipment
Hydraulic crush fixture (0–200 kN), programmable charge/discharge cycler, blast-rated test enclosure
Pass Result
100% lot sampling · Zero field failures across 2.1M cells shipped FY2024
Lithium Battery Transport Testing
United Nations Recommendations

Eight-test sequence required for air, sea, and ground transport of lithium batteries. We maintain a dedicated UN 38.3 test lab on-site — clients receive full test summary documentation with every shipment.
Test Protocol
T1–T8 Transport Simulation Sequence
Equipment
Altitude simulation chamber, thermal cycling oven (−40°C to +75°C), vibration table (7–200 Hz)
Pass Result
Full T1–T8 documentation provided per lot · DGD-compliant shipping labels included
Quality Management System
International Organization for Standardization

Every production run operates under our ISO 9001-certified QMS. Lot traceability is maintained from cell receipt through pack serialization — each finished pack carries a laser-etched serial number linked to its full build record.
Test Protocol
QMS Audit + Pack-Level Traceability Verification
Equipment
Laser marking station (class-4 UV), MES traceability system, automated optical inspection (AOI) line
Pass Result
Recertified annually · Last audit score: 98/100 · Zero major non-conformances since 2021
Cell to Pack
How the Line
Actually Runs.
No black boxes. Here's the exact sequence from incoming cells to certified pack — every step with hard pass criteria.

Cell Sourcing & Incoming QC
We source prismatic, pouch, and cylindrical cells exclusively from Tier-1 manufacturers with verified chain-of-custody documentation. Every incoming lot undergoes capacity grading, internal resistance matching, and self-discharge screening before entering the line.
100%
Incoming lots screened

Module Assembly & Spot Welding
Automated spot welding stations apply nickel or aluminum busbars with ±0.05mm positional accuracy. Every weld joint undergoes inline pull-testing at 45N minimum — any weld below spec triggers immediate line stop and root-cause analysis.
45N
Minimum weld pull force

Thermal Runaway & BMS Integration
Battery management systems are calibrated and flashed on-line. Each pack runs a 4-hour formation cycle followed by thermal imaging at load — hotspots above 3°C delta trigger immediate quarantine. Cell-to-cell thermal runaway propagation barriers are installed per UL 9540A geometry.
3°C
Maximum thermal delta threshold

Pack Sealing & IP Certification
Enclosures are sealed in our positive-pressure clean room to IP67 or IP68 depending on application. Helium leak testing is performed on every sealed pack — pass criteria is less than 1×10⁻⁵ mbar·l/s. Final laser engraving links the pack serial to its full MES build record.
IP68
Sealing standard available
Production Availability
Available Slots.
Real Numbers.
We run a closed-loop capacity model — slots are allocated by quarter and filled on a first-reviewed basis after NDA execution.
0 GWh
Annual Production Capacity
0%
First-Pass Yield FY2025
0
Active Client Programs
2 of 6 slots
Validated designs only
5 of 6 slots
Concept-to-production accepted
6 of 6 slots
Large-volume OEM preferred
6 of 6 slots
NDA required for slot reservation
Minimum Order Thresholds
Validated design required · DFM review included · NRE applies
Full production run · Dedicated line time · Volume pricing
Dedicated capacity block · On-site client liaison · Custom SLA
Active Programs
Who We Build
Packs For.
Client identities are protected under NDA. Categories and volumes are disclosed with permission.
EV Startup
~3,200 packs/yr
Solar Storage OEM
~8,500 packs/yr
Industrial Equipment
~1,800 packs/yr
Marine Propulsion
~900 packs/yr
Grid-Scale ESS
~12,000 packs/yr
Aerospace GSE
~420 packs/yr
You've Passed the Audit
Ready to Reserve Your Slot?
The Capacity Review takes 20 minutes. We'll confirm certification alignment, review your pack spec, and hold a production slot under NDA while you finalize procurement approval.
NDA executed before any spec disclosure